logo
Inicio Productosequipo de prueba no destructivo

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

Los Mejores Productos
Certificación
CHINA HUATEC  GROUP  CORPORATION certificaciones
CHINA HUATEC  GROUP  CORPORATION certificaciones
Comentarios de cliente
productos de gama amplia de NDT, podemos conseguir todo en el grupo de huatec. Preferimos comprar de ellos. Rusia Rudolf Shteinman

—— Rudolf Shteinman

Tengo gusto del servicio, respuesta muy rápida, trabajo profesional. Aret Turquía

—— ARET Kaya

probador de dureza de huatec, muy buena calidad, estamos muy satisfechos con el probador de dureza portátiles la BSR-50. Kumaren Govender Sotuth África

—— Kumaren Govender

Estoy en línea para chatear ahora

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization
HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

Ampliación de imagen :  HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

Datos del producto:
Lugar de origen: Porcelana
Nombre de la marca: HUATEC
Certificación: ISO,CE
Número de modelo: HCDX-1500
Pago y Envío Términos:
Cantidad de orden mínima: 1 unidad
Detalles de empaquetado: en caja de cartón
Tiempo de entrega: 15-25 días después del pago
Condiciones de pago: T/T, Paypal, L/C, Western Union
Capacidad de la fuente: 100 juegos por mes

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

descripción
Corriente de CA: 0-1500A Fuente de alimentación: 220 V (sistema de dos fases de tres cables) ± 10%, 50 Hz, corriente instantánea es de aproximadament
Método de magnetización: Magnetismo de CA, magnetismo de CC (HWDC/FWDV) Cable de la salida: 2 Cables flexibles de núcleo de cobre (120 mm2) de 3 metros
Estabilidad de la remanencia: ≤±5% Nombre del producto: Detector de fallas de partículas magnéticas móviles
Resaltar:

HCDX-1500 magnetic particle flaw detector

,

mobile AC/HWDC flaw detector

,

movable flaw detector with demagnetization

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization  


The HCDX-1500 mobile magnetic particle flaw detector can magnetize parts in AC (or half wave DC magnetization HWDC). And with automatic demagnetization function, no additional demagnetization device is required.

8-bit MCU is adopted as the controller by this magnetic particles flaw detector, and the continuous regulation of magnetizing current can be realized through the precise collection of the AC zero voltage crossing signal and the signal of current regulation. It has the function of maximum current limit. With the function of phase controlled, the detector is suitable for both continuous technique and residual technique.


The current value is displayed on the analog ammeter or digital ammeter. The prod sets and trigger button are for operating in the narrow space.

The output current is reduced from the initial value to zero automatically when demagnetizing. Non-contact switch is adopted for the equipment.

This detector can be connected to the prod sets (handheld electrode sets) or spiral cable (flexible coil). Also there are some coils or electrodes designed for this equipment to become a simple inspection machine tool as option.


Technical parameters:

AC magnetization current

AC 0~1500A (effective value) continuously adjustable, short-time intermittent power, with power off phase control;

HWDC: 0~1500A (twice the average) continuously adjustable, short-time intermittent power;
Automatic demagnetizing current AC/HWDC 1500A~0 continuously adjustable, demagnetization time is shortened with the decrease of current
Output cable 2 copper-core flexible cables (120mm2) of 3 meters
Power supply 220V (two-phase three-wire system) ±10%, 50Hz, instantaneous current is about 100A
Dimensions 900(L)× 450(W)×950(h) mm; (not include the handle
Remanence stability ≤±5%
Temporary load rate ≤30%
Input voltage 380V 50Hz
Demagnetization time < 5s
Weight about 120kg


Main functions:

Detection methods: support rod method, winding method, coil method

Magnetization method: AC magnetization, DC magnetization (HWDC), pulse magnetization

Demagnetization method: AC demagnetization using far away method demagnetization (attenuation method), AC demagnetization using ultra-low frequency demagnetization


Standard configuration:

Mobile host 1pc

Support rod probe 1 set

robe cable 1pc

Foot switch 1pc

Optional accessories

Fixed coil

Wound cable

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

Contacto
HUATEC GROUP CORPORATION

Persona de Contacto: Ms. Shifen Yuan

Teléfono: 8610 82921131,8618610328618

Fax: 86-10-82916893

Envíe su pregunta directamente a nosotros (0 / 3000)